UL Labelled Doors
These doors meet NFPA 252 standards and are tested in accordance
to UL10 b and UL 10 c. The range includes temperature rise and non-temperature rise fire rated doors.
UL (Underwriters Laboratories) is a global independent safety science company with more than a century of
expertise innovating safety solutions safeguarding people, products and places and providing peace of
mind.
UL label doors carry a UL Metal label on the doors and frames with the respective file number which gives details of the fire rating and type. The file number can be checked online at the UL website for validating claims made by the company.
In-ArcUL Label products offers the architect and consultant community a number of options in door designs and hardware to meet various design and functional requirements especially in areas of fire containment.
Application
These doors are ideally suited for application in:
- Office entrances
- Educational institutions
- Health care Segment
- Pharmaceutical & Food Processing Zone
- Metro Railway Stations
- Airports
- Shopping Malls
- Industrial Plants
- Multiplexes
- Hotels
- Auditoriums
- Software Parks
- Restaurants
Range: | Flush Doors Doors with vision lite (glazed panels) |
Materials: | Galvanised steel (GI) / Stainless steel (304 Grade, number 4 finish) |
Sheet Thickness: | Standard - 1.2mm for the shutter and 1.6mm for the frame |
Shutter Thickness: | 46 mm |
Infill: | Honeycomb core / Polyurethane / Mineral wool / steel stiffened |
Vision lite: | Minimum 0.0645 Sq. Mtr. and max. up to 0.835 Sq. Mtr. per vision lite. |
Door Sizes (maximum and minimum)
Type | W / H | Min (mm) | Max (mm) |
---|---|---|---|
Single door (Frame Inner to Inner) | Width | 357 | 1114 |
Single door (Frame Inner to F.F.L) | Height | 707 | 3000 |
Pair of doors (Frame Inner to Inner) | Width | 717 | 2302 |
Pair of doors (Frame Inner to F.F.L) | Height | 707 | 3000 |
Door Preparation and Hardware:
All doors are prepared for ANSI grade hardware as recommended or specified.